Showing posts with label Structure. Show all posts
Showing posts with label Structure. Show all posts

Tuesday, September 20, 2011

Importance of Space and other Needs for Plants

  From what Carl has taught us about understanding the plants' needs, we need to imagine and to relate ourselves to plants:  If we are a plant in a greenhouse, what would we need?  For example, there will be weeks of hot weather during summer, and how would we know if the greenhouse is too hot?  The answer is simple: If we, the workers in the greenhouse, can feel the heat and the need to cool down and drink more water, the plants will need to as well.

  As silly as it may sound initially, treating plants as someone like us is easier for us to understand their needs.  Space for plants must not be neglected - cramming too many plants per square meter will result in plants not getting enough sunlight in the future.  We all want huge output,but 2.5 - 2.6 plants per meter squared seems to be the recommended density.

  Plants do get stressed out as well.  According to Kyra, when the weather gets very hot, ~27 degrees celcius and above, plants are usually stressing at that point.  If we pick or prune or twiddle when the plants are stressing, it usually results in the plants "giving up" and they end up not producing anymore output.  This is important to note, and it is the reason why workers do not usually do anything with the plants after 2pm, which is when it gets really hot.

  Plants also need sufficient space above them called buffer.  Note the picture below:  The space above the plants' heads to the beams supporting the roof is the buffer zone.  Buffers are important for the air to mix inside the greenhouse for stable and equal temperature and heat throughout the greenhouse, which is aided by fans hanging above the plants.  The larger the buffer, the better it is for the plants.  For example, tomatoes need huge buffers to prevent their heads from overheating and killing the plant since they grow very tall. 

Poly sheets covering that is used for protecting against
scorching sunny days or containing the heat
inside the greenhouse during cold weathers.

  Notice the sheets that is being dragged slowly to the right.  This poly sheet wears out every 2 years and needs to be replaced.  It protects the greenhouse from heavy sun rays and also prevents the heat from leaving the greenhouse during cold days. 

More sheets at the side, but this is always there and
only replaced and taken down during clean up.
Note the generous buffer zone for the plants.

Saturday, September 17, 2011

Irrigation in Merom

3 tanks containing water.

  There are 3 tanks containing enough water for 2 days in case of an emergency water cut off.  One tank contains returned water after irrigation (Carl calls it recert).  The other two contains a mixture of rain, city, and well water.  Well water this year contains high level of sodium, so we use Phosphoric acid during the fertilizer mixing process to lower the pH level before irrigating plants.

One of the filter pump stations.
  There are also 8 tanks of filter pumps that the mixed water with fertilizer goes through before heading to the plants.  These tanks contain filter sand that gets rid of tiny garbage that may clog the pipes.  The garbage could be weeds growing on the water, piece of construction material that went in the fertilizer tank, and so on.  The filter sand is replaced every year in the cleaning season (December).

Filter sand stock.
  The pure water and recert water merge at one point in the pipe.  Then the machine that monitors both the pH level of mixed water and the fertilizer draws just the right amount from the two to make the perfect mix for irrigation.  The perfect mix is stored in the large tank located in the irrigation room and sent off to the plants every so often.  Of course, the frequency and duration of irrigation depend on temperature, climate, plant conditions, and many other factors.

  We also have to occasionally clean out the tanks since weed will grow on the surface.
Dried sand-like weed that is thrown out from
the water tank.
They look very green and moldy in the tanks.
Weed in a tank of water already mixed with fertilizers.
  It is important to note that recert water from certain plants cannot be immediately reused to water certain plants.  For example, excess water used for watering tomato plants must not be used to water tomato plants again because there might be viruses from the plants that got into the recollection sewer.  According to Carl, a sterilizing system is the better choice to counter this problem since the payback is 3 years compare to just wasting water.  The sterilization can be done in multiple ways, one of which is ultraviolet radiation.  The following are some of the water we can and can't reuse for.


  • Bell pepper water can be reused to water bell pepper
  • Cucumber water can't be reused to water cucumber
  • Tomato water can't be reused to water tomato
  • Cucumber water can be reused to water tomato
  • Tomato water can be reused to water cucumber

  For more information about how the fertilizer is prepared, refer to the Fertilizer in Merom. (hyperlink to be added)

Friday, September 16, 2011

Water System for a Greenhouse

Currently at Merom, there is one giant big tank outside the facility for hot water circulation. The water is heated in the boiler room using natural gas instead of the wood burner since it's more cost efficient.  That tank is part of the enclosed heating system for the entire facility, including phase 1, 2 and 3. All the water is circulated, and the tank contains sensors for both the temperature and the water level. If the water level is below a certain level, alarm will notify the facility. The tank also contains 9 temperature sensors, making sure the water is not boiling but kept at a relatively high temperature, around 92-98 Celcius.The water must not boil since it's an enclosed system and the air is not pressurized in the tank.

Hot Water Tank
If the water level drops below a certain level, then we know there is a leakage somewhere in the system since everything is enclosed and all water does not escape. Natural gas is used to heat up the water, and it mixes with cold water in a mixing valve to obtain the desire temperature before sending the water off to the heating pipes to heat up the greenhouse.


Tuesday, September 13, 2011

Priva Maximizer

Priva Maximizer is the control system we use in 248x52 greenhouse.  Priva Maximizer automates important controls in the greenhouse to save our time.  We can access the system through two user interfaces: buttons and display on the Priva Maximizer and a PC display.

The buttons and display on Priva Maximizer.
There are six sets of wires that transmits the control signals across the greenhouse.  Each set partakes different set of inputs/outputs to specific zones in the greenhouse.

The bottom part of Priva Maximizer.
You can see the six pink wires sticking out.
The six wires coming out from the office.
The wires splitting.  Two go right, four go left.
The two wires to the right go to irrigation control and boiler room.  At the irrigation, the system opens/closes pipes that convey water (with fertilizer mix) to the plants.  The amount of fertilizer mix that is pumped to the pipe is also controlled by Priva Maximizer.  The system keeps track of flow direction to prevent backwash system.  For further information, refer to the Priva Maximizer operation manual.

The thick pink wire (right) coming in to the irrigation
control.  The thinner wires (left) go to irrigation valve
and other control (e.g. fertilizer pulse).
Control signal sent to irrigation valve.  When the valve
is opened, water flows to the plants.
A complex control box for I-dunno-what.
Pulses of fertilizer from the tube are mixed to the
irrigation pipe.
In the boiler room, the control signal controls the heating of the greenhouse.  Unfortunately we are not heating the greenhouse at all because, according to Carl, the greenhouse is not making enough money and thus not worth heating.  I don't know the electricity expense to crop output ratio, but I think it is a waste of investment.

The wire incoming to the boiler room control box.
A closer look to the control box.

Another closer look.

Thin pink wires coming from the control box to control
the amount of boiled water sent to heat the greenhouse.

Bottom part of the boiler.
A closer look.
Going back to the remaining four wires, one of them goes to the antenna located on top of the greenhouse.

Pink wire receiving data from the antenna.
The antenna has five visible sensors attached.  I will explain the detail of each sensor, but I am not entirely confident about the correctness.  The farthest right is the wind direction sensor, where the sensor is supposed to be calibrated (pointed) to the north.  In the picture, however, the sensor is pointing southeast and I need to verify why.  The farthest left, a Mickey-mouse-like spinney blade, is a wind speed sensor.  The second from the left is an aspirated temperature/humidity sensor.  The two remaining similar ones are rain and sunlight sensors.  I hope I'm right.

The remaining three wires split, one to the small
and two to the big greenhouse.
A control wire to the control box in the small greenhouse.

A motor that controls the ventilation. 

A burner that supplies CO2.
A control box of I-dunno-what.

An aspirated temperature/humidity sensor.  This is
located in multiple locations.
We are not utilizing all the functions provided by the Priva Maximizer.  For example, we can't use burner to supply CO2 to the plants.  We don't heat up the greenhouse to stimulate the plant growth.  Maybe it is costly, maybe it is just cumbersome, but that's the current policy of Carl.

Monday, September 12, 2011

The Greenhouse Structure And the Fertilizers

Current greenhouse is relatively small by size.  It features two front entrances: a normal door and two sliding doors.  There's also two sliding doors in the back of the greenhouse which is used for dumping bad crops and trimmed plants.

The greenhouse currently uses three fertilizers: Magnesium Sulphate, Potassium Nitrate, and Calcium Nitrate.







Four buckets containing mixture ratios of fertilizers.
Huge tanks containing water.
Steel wires are hung across the greenhouses from
one end to the other for the strings' supports.
The sliding doors at the back of the greenhouse
for dumping bad crops and pruned materials.

The unused entrance.

Carl usually opens these sliding doors and move
his truck here for picking up/dropping off totes.


Two unused offices.  One of them contains the computer
system governing all the
water supply/window opening mechanisms.

Heating pipes which also work as railings.

Pipes protrude onto the cement floor
for easier cart maneuvering onto the pipes.

Steel chains supporting more
steel wires for the strings supports.

Some strings don't need chains; they are
supported by the beams of the structure.

Collected strings from fallen plants.

Basic cart and totes.



Sunday, September 11, 2011

Stopping Waterflow To Certain Rows

To save money on water, we cut off the water supply to certain rows, such as a row of dead and drying tomato plants.  Do be careful to not cut off water supply accidentally as some rows may contain a few alive plants.

One end of the water pipe supplying water to
the watering tips.
The other end of the water pipe is usually
connected to the main water supply pipe.
In this case, a cap is screwed to the
main water supply pipe to stop the water supply.

The front end of the water pipe can also be "folded"
and "locked" with a PVC pipe instead of a cap.

Notice that the caps at the ends of the pipes are the same, so we could just unfasten the cap at one end, which is the shown in the first picture, and use that to block the white main pipe from supplying water to the black pipe.